Dishwasher Spec Check
Commercial undercounter dishwashers · 5-model pilot

Voltage is only the first check.

Compare the installation facts scattered across specification sheets and manuals. See where the documents agree, where they differ, and what still needs checking before an order.

5 model comparisons · 2 manufacturers · documents read November 8, 2026

Compare published model facts

Published nominal voltage label
Sanitizing method

Filters search document labels, not your building's compatibility. UC50e voltage documents disagree; its current spec labels are shown. 230 V is not silently treated as 240 V.

5 model comparisons

Hot-water sanitizing

01CMA 180UC-3

Documented circuit recommendation

The running load is not the recommended supply circuit.

Published supply
208 V or 240 V, single-phase
Running load
30 A at 208 V; 32 A at 240 V
Nominal frame
24 in wide ×25 in deep ×33.25 in high

Open the model notes for missing fields and document conflicts. This listing does not confirm it works on your supply.

Compare source details →
Hot-water sanitizing

02CMA UC50e

Voltage revision warning

The current spec and older manual do not use the same voltage labels.

Published supply
2024 spec: 208 V or 240 V, single-phase
Running load
2024 spec: 27 A at 208 V; 30 A at 240 V
Nominal frame
23-7/16 in wide ×24 in deep ×33-5/16 in high

Open the model notes for missing fields and document conflicts. This listing does not confirm it works on your supply.

Compare source details →
Chemical sanitizing

03CMA L-1X16

Option and height warning

Heater options and document revisions matter.

Published supply
2024 spec: 115 V
Running load
2024 spec: 16 A; older manual: 15.8 A
Nominal frame
2024 spec: 24 in wide ×23.5 in deep; height 33.25-34.25 in

Open the model notes for missing fields and document conflicts. This listing does not confirm it works on your supply.

Compare source details →
Chemical sanitizing

04Jackson DishStar LT

LT only, not LT-H

The LT and LT-H are separate configurations.

Published supply
115 V,60 Hz, single-phase
Running load
LT: 10 A total load in the 2026 manual
Nominal frame
24.25 in wide ×25 in deep ×33-5/16 in high. Manual notes 1 in foot adjustment.

Open the model notes for missing fields and document conflicts. This listing does not confirm it works on your supply.

Compare source details →
Hot-water sanitizing

05Jackson DishStar HT

HT only, not HT-E

230 V is the published label. It is not silently relabeled 240 V here.

Published supply
208 V or 230 V,60 Hz, single-phase
Running load
37.2 A at 208 V; 40.7 A at 230 V
Nominal frame
24.25 in wide ×25 in deep ×33-5/16 in high. Manual notes 1 in foot adjustment.

Open the model notes for missing fields and document conflicts. This listing does not confirm it works on your supply.

Compare source details →

The details a voltage filter misses

Running load versus supply circuit

A stated current draw does not by itself state the breaker, conductor or service requirement. The CMA 180UC-3 manual lists 30/32 A running load and separately recommends a minimum 40 A dedicated circuit.

Similar names, different options

DishStar LT is not LT-H. DishStar HT is not HT-E. The L-1X16 heater option needs explicit confirmation. We do not merge these configurations to fill blanks.

Machine height versus usable counter space

A nominal frame height is not a promise that the machine can be installed in the same-size opening. Adjustable feet, door travel, connections, ventilation and access can need more room.

Use the before-order checklist →