Model-specific cautions
This is DishStar HT, not HT-E, HT-E-SEER or another similarly named configuration. Do not use another model's voltage or phase options.
Manufacturer documents say electrical figures are reference values. Actual data-plate values and local installation requirements control.
What the inspected documents say
- Published supply
- 208 V or 230 V,60 Hz, single-phase
Read manufacturer source ↗ - Running load
- 37.2 A at 208 V; 40.7 A at 230 V
Read manufacturer source ↗ - Supply circuit
- Not specified as a breaker recommendation in the inspected electrical table. Do not use load as breaker size.
Read manufacturer source ↗ - Wiring
- L1,L2 and ground in the 2026 manual diagram
Read manufacturer source ↗ - Nominal frame
- 24.25 in wide ×25 in deep ×33-5/16 in high. Manual notes 1 in foot adjustment.
Read manufacturer source ↗ - Dish opening
- 14.25 in clearance
Read manufacturer source ↗ - Drain limit
- Manual drawing: connection at or below 24 in. Confirm the drain route with the installer.
Read manufacturer source ↗ - Incoming hot water
- 110°F minimum in the 2026 manual parameter table
Read manufacturer source ↗
Owning source documents
Read the full current documents, not only this summary. A source-read date is not a manufacturer confirmation for your serial number.
- Jackson current DishStar HT product pagehttps://www.jacksonwws.com/products/dishstar-ht-undercounter/
- Jackson DishStar HT/LT/LT-H manual, revisionU, June 4, 2026https://www.jacksonwws.com/wp-content/uploads/2016/08/DishStar-Manual.pdf
What this entry does not establish
Current inventory, quoted configuration, delivered cost, installation approval, local ventilation requirements, current certification, and your building's capacity are not established here. No price or dealer specification database is copied into this comparison.