Model-specific cautions
Check the exact machine data plate, supply and current installation documents with a qualified installer. A nominal frame dimension does not include all service or operating space.
The 2024 spec contains a Celsius conversion inconsistency for 120°F. This guide uses the newer manual's Fahrenheit minimum instead.
What the inspected documents say
- Published supply
- 208 V or 240 V, single-phase
Read manufacturer source ↗ - Running load
- 30 A at 208 V; 32 A at 240 V
Read manufacturer source ↗ - Supply circuit
- Manufacturer recommends a minimum 40 A dedicated circuit. This is not an electrician's assessment.
Read manufacturer source ↗ - Wiring
- Two power conductors and ground; no neutral required by this manual.
Read manufacturer source ↗ - Nominal frame
- 24 in wide ×25 in deep ×33.25 in high
Read manufacturer source ↗ - Dish opening
- 14.5 in maximum ware clearance
Read manufacturer source ↗ - Drain limit
- Standpipe no higher than 22 in, per manual.
Read manufacturer source ↗ - Incoming hot water
- Minimum 120°F; recommended 140°F
Read manufacturer source ↗
Owning source documents
Read the full current documents, not only this summary. A source-read date is not a manufacturer confirmation for your serial number.
- CMA current product pagehttps://cmadishmachines.com/product/180uc-3/
- CMA 180UC-3 manual, revision 1.00BC, October 1, 2025https://cmadishmachines.com/wp-content/uploads/2024/06/180UC-3_Installation_Operation_Manual_Rev_1.00BC_10-01-2025.pdf
- CMA 180UC-3 specification, September 2024https://cmadishmachines.com/wp-content/uploads/2024/06/180UC-3_Spec_Sheet_09-2024.pdf
What this entry does not establish
Current inventory, quoted configuration, delivered cost, installation approval, local ventilation requirements, current certification, and your building's capacity are not established here. No price or dealer specification database is copied into this comparison.